Hemoglobin Camperdown [β104Arg→Ser] Detection During Hemoglobin A1c Measurement via Capillary Electrophoresis

2016 
Dear Editor, Reports on the analytical evaluation of capillary electrophoresis (CE) for glycated hemoglobin (HbA1c) measurement have already been published [1]. There have been several recent reports concerning the impact of the presence of hemoglobin variants on HbA1c measurement with the CE method. One study focused on the analytical interference of some hemoglobin variants [2], demonstrating that hemoglobin variants S, C, D, and E do not interfere either with HbA1c measurement or the glycation rate of hemoglobin variants, which is equal to the glycation rate of HbA. In a second report, analytical evaluation of CE showed that hemoglobin variant E and β-thalassemia do not affect HbA1c results. Moreover, most hemoglobin variants common to China can be detected by using a CE analyzer, and HbA1c values do not seem to be affected [3]. We report a case of hemoglobin Camperdown (HbCa) detected by using a Capillarys 2 Flex Piercing instrument (C2FP, Sebia, Lisses, France) during HbA1c measurement. A 76-yr-old man receiving follow-up care for type 2 insulin-dependent diabetes was admitted to our hospital for a necrotic wound on the heel. To manage the diabetes, HbA1c was measured on a C2FP instrument in our clinical biology laboratory at Rouen University Hospital, France. The CE software flagged an alarm stating "Atypical profile" with an HbA1c value of 4.2% (22 mmol/mol). We observed an abnormality on the electropherogram (Fig. 1), with a peak of unknown hemoglobin quantified at 3.0% and named fraction 1 by the CE software. There was no other abnormality on the electropherogram. The sample was also tested with a Bio-Rad Variant II analyzer (Bio-Rad, Marnes-la-Coquette, France) in the clinical biology laboratory at Le Havre General Hospital, France, which measured the HbA1c value at 52.2% (547 mmol/mol) because of migration of a probable hemoglobin variant in the HbA1c zone. Concentration of fructosamine (261 µmol/L; 205-260 µmol/L) was just above the reference values, which was not consistent with the two HbA1c values obtained. The patient's last HbA1c measurement was performed in our laboratory 10 yr previously. At that time, we observed a peak of unknown hemoglobin on HPLC (Variant, Bio-Rad), and we were not able to quantify HbA1c. The unknown hemoglobin was identified in the National Hemoglobinopathy Reference Laboratory (Creteil, France) as HbCa [β104Arg→Ser]. Ten years ago, the percentage of HbCa was estimated at 51.5%, which was consistent with a heterozygote patient. We supposed that the unknown fraction 1 on the electropherogram was the glycated fraction of HbCa. We observed that both glycated fractions were clearly separate, unlike HbCa and HbA0, which exactly coeluate, explaining the abnormal value of HbA1c calculated by the CE software. A manual off-line recalculation of the global glycated fractions percentage was performed, by integrating the sum of both peaks instead of HbA1c with the formula for percentage of glycated fractions=(HbA1c+HbCa1c)/(Total HbA0 peak)×100. We then applied the calibration equation of the software, thereby obtaining a value of 6.3% (45 mmol/mol) for global glycated fractions. Fig. 1 Abnormal electropherogram obtained by Capillarys 2 Flex Piercing instrument. Abnormal electropherogram with software alarm "atypical profile" showing a peak of unknown hemoglobin (HbCa1c), which is the glycated form of hemoglobin Camperdown (HbCa). HbCa ... HbCa is a rare variant, first described in 1974 [4], which is not associated with hematological abnormalities. Hemoglobin variants can affect the accuracy of HbA1c measurement, resulting in interference. This interference depends on the type of hemoglobin variant and the method used. Recently, Gaborit et al. [5] published the effects of this variant on HbA1c measurement using HPLC and immunoassay methods. They concluded that it was not possible to measure the exact HbA1c value with the affinity chromatography method. Moreover, immunoassay methods are blind to detecting such variants and probably underestimate HbA1c values. Herein we describe for the first time a case of HbCa interfering with CE HbA1c measurement. The C2FP HbA1c method is not able to differentiate HbA0 from HbCa. The presence of an unknown peak must alert the pathologist. The CE software value is affected by negative bias due to the co-elution of HbCa and HbA0. Manual recalculation seems to yield good results for global glycated fractions, consistent with fructosamine. However, the threshold for HbA1c values must be applied with great care. In fact, the glycated rate of this rare variant has not yet been validated by any publication in the literature. Fructosamine, glycated albumin, or daily capillary blood glucose remain good markers to manage such patients.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    6
    References
    1
    Citations
    NaN
    KQI
    []