Positive Airway Pressure Therapy Adherence with Mask Resupply: A Propensity-Matched Analysis.

2021 
There are currently few data on the impact of mask resupply on longer-term adherence to positive airway pressure (PAP) therapy. This retrospective analysis investigated the effects of mask/mask cushion resupply on the adherence to PAP versus no resupply. Deidentified patient billing data for PAP supply items were merged with telemonitoring data from Cloud-connected AirSense 10/AirCurve 10 devices via AirViewTM (ResMed). Eligible patients started PAP between 1 July 2014 and 17 June 2016, had ≥360 days of PAP device data, and achieved initial U.S. Medicare adherence criteria. Patients who received a resupply of mask systems/cushions (resupply group) were propensity-score-matched with those not receiving any mask/cushion resupply (control group). A total of 100,370 patients were included. From days 91 to 360, the mean device usage was 5.6 and 4.5 h/night in the resupply and control groups, respectively (p < 0.0001). The proportion of patients with a mean device usage ≥4 h/night was significantly higher in the resupply group versus the control group (77% vs. 59%; p < 0.0001). The therapy termination rate was significantly lower in the resupply group versus the control group (14.7% vs. 31.9%; p < 0.0001); there was a trend toward lower therapy termination rates as the number of resupplies increased. The replacement of mask interface components was associated with better longer-term adherence to PAP therapy versus no resupply.