Performance monitoring of EBUS for the staging and diagnosis of lung cancer: auditing the Greater Manchester EBUS service against new national standards.

2021 
Introduction Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a pivotal test in lung cancer staging and diagnosis, mandating robust audit and performance monitoring of EBUS services. We present the first regional cancer alliance EBUS performance audit against the new National EBUS specification. Methods Across the five EBUS centres in the Greater Manchester Cancer Alliance, data are recorded at the point of procedure, when pathological results are available and at 6 months postprocedure to review any further pathological sampling (eg, at surgical resection) and the outcome of clinical–radiological follow-up. Outcomes across all five centres were compared with national standards for all lung cancer EBUS procedures from 01 January 2017 to 31 December 2018. Results 1899 lung cancer staging or diagnostic EBUS procedures were performed across the five centres during the study period; 1309 staging EBUS procedures and 590 diagnostic EBUS procedures. Major complications were seen in six cases ( 85% of procedures performed within 7 days of referral. Conclusion The National EBUS service specification is an important framework to drive the quality of EBUS services across the UK. Our data provide assurance of appropriate performance and safety while also highlighting specific areas for attention that can be addressed with the support of the cancer alliance.