Usefulness of automated assays for detecting hepatitis B and C markers in dried blood spot samples
2019
Objective
Dried blood spots (DBSs) can be used as an alternative to serum samples because they are easily collected and can be transported without refrigeration to reference laboratories for diagnosis. The present study was performed to evaluate the utility of electrochemiluminescence immunoassay “ECLIA” for anti-HCV, HBsAg and anti-HBc detection from DBS samples.