盖住的自我有为避免 stent 赶出的胰腺的 pseudocyst 的在内的闪耀的塑料的可扩充的金属性的 stent

2012 
Endoscopic ultrasound-guided drainage has recently been recommended for increasing the drainage rate of endoscopically managed pancreatic fluid collections and decreasing the morbidity associated with conventional endoscopic trans-mural drainage. The type of stent used for endoscopic drainage is currently a major area of interest. A covered self expandable metallic stent (CSEMS) is an alternative to conventional drainage with plastic stents because it offers the option of providing a larger-diameter access fi stula for drainage, and may increase the fi nal success rate. One problem with CSEMS is dislodgement, so a metallic stent with flared or looped ends at both extremities may be the best option. An 85-year-old woman with severe comorbidity was treated with percutaneous approach for a large (20 cm) pancreatic pseudocyst with corpuscolated material inside. This approach failed. The patient was transferred to our institute for EUS-guided transmural drainage. EUS confi rmed a large, anechoic cyst with hyperechoic material inside. Because the cyst was large and contained mixed and corpusculated fluid, we used a metallic stent for drainage. To avoid migration of the stent and potential mucosal growth above the stent, a plastic prosthesis (7 cm, 10 Fr) with flaps at the tips was inserted inside the CSEMS. Two months later an esophagogastroduodenoscopy was done, and showed patency of the SEMS and plastic stents, which were then removed with a polypectomy snare. The patient experienced no further problems.