Quantification of a panel for dry-eye protein biomarkers in tears: A comparative pilot study using standard ELISA and customized microarrays.

2021 
Purpose This paper examines the tear concentration of cystatin S (CST4), calcyclin (S100A6), calgranulin A (S100A8), and matrix metalloproteinase 9 (MMP9), and the correlation between biomarker expression, clinical parameters, and disease severity in patients suffering from dry eye (DE). A comparison of the results is obtained via ELISA tests and customized antibody microarrays for protein quantification. Methods This single-center, observational study recruited 59 participants (45 DE and 14 controls). Clinical evaluation included an Ocular Surface Disease Index (OSDI) questionnaire, a tear osmolarity (OSM) test, the Schirmer test (SCH), tear breakup time (TBUT), fluorescein (FLUO) and lissamine green (LG) corneal staining, and meibomian gland evaluation (MGE). Tear concentrations of CST4, S100A6, S100A8, and MMP9 were measured using standard individual ELISA assays. The levels of CST4, S100A6, and MMP9 were also measured using customized multiplexed antibody microarrays. Correlations between variables were evaluated, and a significance level was p value <0.05. Results The quantification of tear protein biomarkers with ELISA showed that the concentration of CST4 was significantly (2.14-fold) reduced in tears of DE patients in comparison with control (CT) subjects (p < 0.001). S100A6 and S100A8 concentrations were significantly higher in the tears of DE patients (1.36- and 2.29-fold; p < 0.001 and 0.025, respectively) in comparison with CT. The MMP9 level was also higher in DE patients (5.83-fold), but not significantly (p = 0.22). The changes in CST4 and S100A6 concentrations were significantly correlated with dry eye disease (DED) severity. Quantification of CST4, S100A6, and MMP9, using antibody microarrays, confirmed the ELISA results. Similar trends were observed: 1.83-fold reduction for CST4 (p value 0.01), 8.63-fold increase for S100A6 (p value <0.001) and 9.67-fold increase for MMP9 (p value 0.94), but with higher sensitivity. The biomarker concentrations were significantly associated with the signs and symptoms related with DED. Conclusions S100A6, S100A8, and CST4 diagnostic biomarkers strongly correlate with DED clinical parameters. S100A6 and CST4 are also useful for grading DE severity. The multiplexed antibody microarray technique, used here for tear multi-marker quantification, appears more sensitive than standard ELISA tests.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    52
    References
    1
    Citations
    NaN
    KQI
    []