Descending Aorta Diameters as Predictor of Late Adverse Outcomes in Patients with Uncomplicated Type B Aortic Dissection: A Systematic Review and Meta-Analysis.

2021 
BACKGROUND A subset of patients with uncomplicated type B aortic dissection (uTBAD) has been shown to possess higher risk of experiencing late adverse outcomes. Therefore, we conducted an analysis to investigate the role of descending aorta diameters, including total descending aorta diameter and false lumen diameter, as predictor of late adverse outcomes in patients with uTBAD. METHODS A systematic search was performed through Pubmed, ClinicalKey, ScienceDirect, and Cochrane Library to identify relevant studies. Our primary outcome was the composite late adverse events following their first episode of hospitalization. All meta-analyses were performed using Review Manager version 5.4. RESULTS A total of 2,339 (male 68.8%) patients from a total of 15 cohorts were included in our analysis. During follow-up period, there were 655 (27.3%) and 149 (6.3%) cases of late adverse events and mortality, respectively. Patients with higher initial descending aorta diameter were at higher risk of developing late adverse events (RR 2.99 [2.60, 3.44]; p<0.001) and mortality (RR 3.15 [2.34, 4.25]; p <0.001) throughout follow-up period. Maximum false lumen diameter at the initial presentation seemed to significantly be associated with late adverse events (RR 1.87 [1.46, 2.39]; p <0.001) but not with mortality (RR 2.55 [0.81-8.00; p = 0.11). CONCLUSION Descending aorta diameters, particularly maximum initial descending aorta diameter, is a good and helpful predictor of late adverse outcomes in patients with uTBAD.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    41
    References
    0
    Citations
    NaN
    KQI
    []