OBJECT This study was undertaken to evaluate the impact of postoperative MRI artifact on the assessment of ongoing spinal cord or nerve root compression after anterior cervical discectomy and fusion (ACDF) using a trabecular tantalum cage or bone autograft or allograft. METHODS The authors conducted a retrospective review of postoperative MRI studies of patients treated surgically for cervical disc degenerative disease or cervical instability secondary to trauma. Standard ACDF with either a trabecular tantalum cage or interbody bone graft had been performed. Postoperative MR images were shown twice in random order to each of 3 assessors (2 spine surgeons, 1 neuroradiologist) to determine whether the presence of a tantalum interbody cage and/or anterior cervical fixation plate or screws imparted MRI artifact significant enough to prevent reliable postoperative assessment of ongoing spinal cord or nerve root compression. RESULTS A total of 63 patients were identified. One group of 29 patients received a tan...