Residual Flow After Cerebral Aneurysm Coil Occlusion Diagnostic Accuracy of MR Angiography

2012 
Background and Purpose—The purpose of this study was to estimate the performance measures of MR angiography (MRA) in the diagnosis of aneurysm residual flow after coil occlusion. Methods—Patients having at least 1 cerebral aneurysm treated with coil occlusion were prospectively and consecutively enrolled. Time of flight and contrast-enhanced MRA were performed the same day of the DSA follow-up. The degree of aneurysm occlusion and dimensions of the residual flow were evaluated by independent readers at MRA and digital subtraction angiogram. MRA performance measures were estimated in a cross-sectional analysis and repeated in subgroups of aneurysm sizes and locations. MRA predictive values for recurrence were also estimated using a longitudinal design. Results—We obtained 167 aneurysm evaluations for each imaging modality. Class 3 residual flow was seen on digital subtraction angiogram follow-up in 27%. The sensitivity and specificity of MRA was 88% (95% CI, 80–94) and 79% (95% CI, 67–88), respectively. Th...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    35
    References
    27
    Citations
    NaN