Comparison of two radiographic landmarks for centering the trapezial component in total trapeziometacarpal arthroplasty.

2021 
Abstract We performed a retrospective review of standard anteroposterior and lateral radiographs of the thumb in 80 patients, to compare two radiographic landmarks, in terms of mediolateral bone support, for centering the trapezial component in total joint arthroplasty. On anteroposterior view, we identified the distal articular surface of the trapezium and trapezium width, and defined the two midpoints as radiographic landmarks for positioning a 9-mm trapezial cup. Mean trapezium width was significantly greater than the distal articular surface of the trapezium, and the midpoints did not match. Thus, after positioning simulated 9-mm prosthetic cups centered on each landmark, the residual radial bone distance was significantly greater using the landmark based on trapezium width. The mean value was 33% greater with this landmark, and the minimum value was 2.1 mm, compared to 0.2 mm using the landmark based on the distal articular surface. Our study thus suggested that the midpoint of the trapezium width is the more relevant radiographic landmark for centering the trapezial prosthetic cup in total joint arthroplasty, by preserving better bone stock on the radial side without depleting the ulnar side. On an intraoperative anteroposterior fluoroscopic view, this landmark could be used to check cup positioning.