[LOCATION CHANGE OF ROTATION CENTER AFTER SINGLE SEGMENTAL CERVICAL DISC REPLACEMENT WITH ProDisc-C].

2015 
To evaluate the effectiveness of the single segmental cervical disc replacement with ProDisc-C, and to explore the location change of the flexion/extension center of rotation (COR) of the target level as well as its clinical significance.Between June 2010 and February 2012, 23 patients underwent single segmental cervical disc replacement with ProDisc-C, and the clinical data were retrospectively analyzed. Of 23 patients, 9 were male, and 14 were female with the age range from 27 to 65 years (mean, 45 years), and the disease duration ranged from 10 to 84 months (mean, 25 months). There were 15 patients with radiculopathy, 5 patients with myelopathy, and 3 patients with mixed cervical spondylosis. The involved segments were C4,5 in 5 cases, C5,6 in 14 cases, and C6,7 in 4 cases. Japanese Orthopaedic Association (JOA) score and neck disability index (NDI) were adopted to evaluate the effectiveness. Preoperative and Postoperative radiographic parameters, such as cervical overall range of motion (ROM), target segmental ROM, the adjacent segmental ROM, and intervertebral height were compared. Besides, the location changes of the COR of the target level were further analyzed by the alteration of its coordinates (COR-X, COR-Y), and the relationships between the location changes of the COR and the effectiveness or the radiographic results were analyzed.All the operations were completed successfully; 1 case had hoarseness after operation, which disappeared at 3 months after operation. All cases were followed up 18.3 months on average (range, 6-36 months). There was no device migration, loosening, subsidence, or fracture at last follow-up. The JOA score increased significantly and the NDI score decreased significantly at last follow-up when compared with preoperative scores (P 0.05); while the intervertebral height and the COR-X increased significantly (P 0.05). According to whether the difference of the COR-X between pre- and post-operation was less than the average value 1.86 mm or not, the patients were divided into 2 groups; significant difference was shown in the postoperative target segmental ROM between 2 groups (P 0.05).Single segmental cervical disc replacement with ProDisc-C can obtain satisfactory outcomes. The cervical overall ROM, target segmental ROM, and adjacent segmental ROM can be effectively maintained, and the intervertebral height is increased. The location of the flexion/extension COR of the target segment shifts forward after insertion of the ProDisc-C prosthesis, and the postoperative target segmental ROM becomes smaller as the distance of the displacement of the COR becomes greater.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    0
    Citations
    NaN
    KQI
    []