Hearing loss after spinal anesthesia is related to needle size.

1990 
Audiograms were performed preoperatively and 2 days postoperatively in 28 patients given spinal anesthesia for transurethral resection of the prostate. In 14 patients 22-gauge and in 14 patients 26-gauge spinal needles were used. Hearing loss of 10 dB or more at any frequency was observed in 13 of 1