Background No precise tools exist to predict appropriate shocks in patients with a primary prevention ICD. We sought to identify characteristics predictive of appropriate shocks in patients with a primary prevention implantable cardioverter defibrillator (ICD). Methods Using patient-level data from the Multicenter Automatic Defibrillator Implantation Trial II (MADIT II) and the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT), we identified patients with any appropriate shock. Clinical and demographic variables were included in a logistic regression model to predict appropriate shocks. Results There were 1,463 patients randomized to an ICD, and 285 (19%) had ≥1 appropriate shock over a median follow-up of 2.59 years. Compared with patients without appropriate ICD shocks, patients who received any appropriate shock tended to have more severe heart failure. In a multiple logistic regression model, predictors of appropriate shocks included NYHA class (NYHA II vs I: OR 1.65, 95% CI 1.07-2.55; NYHA III vs I: OR 1.74, 95% CI 1.10-2.76), lower LVEF (per 1% change) (OR 1.04, 95% CI 1.02-1.06), absence of beta blocker therapy (OR 1.61, 95% CI 1.23-2.12), and single chamber ICD (OR 1.67, 95% CI 1.13-2.45). Conclusion In this meta-analysis of patient level data from MADIT-II and SCD-HeFT, higher NYHA class, lower LVEF, no beta blocker therapy, and single chamber ICD (versus dual chamber) were significant predictors of appropriate shocks. This article is protected by copyright. All rights reserved