An MRI-compatible patient rotation system - design, construction, and first organ deformation results

2017 
Purpose Conventionally in radiotherapy, a very heavy beam forming apparatus (gantry) is rotated around a patient. From a mechanical perspective, a more elegant approach is to rotate the patient within a stationary beam. Key obstacles to this approach are patient tolerance and anatomical deformation. Very little information on either aspect is available in the literature. The purpose of this work was therefore to design and test an MRI compatible patient rotation system such that the feasibility of a patient rotation workflow could be tested. Methods A patient rotation system (PRS) was designed to fit inside the bore of a 3T MRI scanner (Skyra, Siemens) such that 3D images could be acquired at different rotation angles. Once constructed, a pelvic imaging study was carried out on a healthy volunteer. T2 weighted MRI images were taken every 45⁰ between 0⁰ and 360⁰, (with 0⁰ equivalent to supine). The prostate, bladder, and rectum were segmented using atlas-based auto contouring. The images from each angle were registered back to the 0⁰ image in three steps: (1) Rigid registration was based on MRI visible markers on the couch. (2) Rigid registration based on the prostate contour (equivalent to a rigid shift to the prostate). (3) Non-rigid registration. The Dice similarity coefficient (DSC) and mean average surface distance (MASD) was calculated for each organ at each step. Results The PRS met all design constraints and was successfully integrated with the MRI scanner. Phantom images showed minimal difference in signal or noise with or without the PRS in the MRI scanner. For the MRI images the DSC (mean±standard deviation) over all angles in the prostate, rectum, and bladder was 0.60±0.11, 0.56±0.15, and 0.76±0.06 after rigid couch registration, 0.88±0.03, 0.81±0.08, and 0.86±0.03 after rigid prostate guided registration, and 0.85±0.03, 0.88±0.02, 0.87±0.02 after non-rigid registration. Conclusions An MRI compatible patient rotation system has been designed, constructed, and tested. A pelvic study was carried out on a healthy volunteer. Rigid registration based on the prostate contour yielded DSC overlap statistics in the prostate superior than interobserver contouring variability reported in the literature. This article is protected by copyright. All rights reserved.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    25
    References
    19
    Citations
    NaN
    KQI
    []