Recombinant hirudin in patients with chronic, stable coronary artery disease. Safety, half-life, and effect on coagulation parameters.

1993 
BACKGROUNDBecause the specific antithrombin hirudin prevents platelet-rich arterial thrombus and accelerates thrombolysis in a variety of animal models, it has promise as antithrombotic therapy. We therefore studied the half-life, effect on anticoagulant parameters, and safety of hirudin in patients with coronary artery disease.METHODS AND RESULTSThirty-eight men and 1 woman (age [mean +/- SD], 60.4 +/- 6.9 years) with angiographic coronary disease were allocated in a single-blind ascending dosage study to a 6-hour i.v. infusion of recombinant hirudin (CGP 39,393) or matching placebo. The median terminal half-life for hirudin, measured by ELISA, was 2.7, 2.3, 2.9, 3.1, and 2.0 hours for the 0.02, 0.05, 0.1, 0.2, and 0.3 mg.kg-1 x h-1 groups, respectively. Activated partial thromboplastin times (aPTT) at 3, 4, and 6 hours were averaged into a plateau value. The aPTT plateau-to-baseline ratios were 1.5 +/- 0.1, 2.0 +/- 0.1, 2.3 +/- 0.1, 2.7 +/- 0.1, and 2.9 +/- 0.1, respectively, with hirudin infused at 0.0...