Comparison of two fixed beta-blocker-pilocarpine combinations

1997 
Purpose. To compare the efficacy and safety of a newly developed ophthalmic solution containing carteolol 2% and pilocarpine (2% (CBS341A) with a timolol 0.5% and pilocarpine 2% fixed combination. Patients and Methods. A randomized, double-masked, multicenter study was conducted in 209 patients with primary open-angle glaucoma or ocular hypertension, whose intraocular pressure (IOP) was higher than 21 mm Hg on bet-blocker twice a day alone. The test medications were administered twice daily for 4 months. IOP was measured at 9 and 11 a.m. at the beginning of the study (with beta-blocker alone) and after one and four months of treatment. Adverse effects were recorded. Results. Both combinations caused a similar, statistically significant decrease in IOP. At four months, in the CBS341A group a 2.4 mm Hg (9%) reduction in IOP was achieved at 9 a.m. and 4. 1 mm Hg (17.3%) at 11 a.m. compared with respectively 3 mm Hg (11%) and 4.5 mm Hg (19.5%) in the timolol-pilocarpine group. No statistical difference was observed between the two groups in safety and efficacy. Conclusions. The carteolol-pilocarpine combination appears as safe and as effective as the timolol-pilocarpine combination in the medical treatment of primary open-angle glaucoma or ocular hypertension.