Vascular ring due to double aortic arch: a rare cause of dysphagia

2004 
Abstract A case of mechanical dysphagia caused by a vascular ring due to double aortic arch is reported. Esophageal stenosis and vascular ring were clearly demonstrated by contrast-enhanced spiral computerized tomography. We emphasize the role of three-dimensional reconstructions with volume rendering in the evaluation of this rare condition.