Wireless, remote solution for home fetal and maternal heart rate monitoring

2020 
Abstract Background Access to prenatal care can be challenging due to physician shortages and rural geography. The multiple prenatal visits performed to collect basic fetal measurements leads to significant patient burden as well. The standard of care tools for fetal monitoring, external fetal heart rate monitoring with cardiotocography, as used today, must be applied by a medical professional in a healthcare setting. Novel tools to enable a remote and self-administered fetal monitoring solution would significantly alleviate some of the current barriers to care. Objective To compare maternal and fetal heart rate monitoring data obtained by 'Invu system' (a wireless, wearable, self-administered, fixed-location device containing passive electrical and acoustic sensors) to cardiotocography, toward a true remote fetal monitoring solution. Study Design A prospective, open-label, multicenter study evaluated concurrent use of Invu and cardiotocography in pregnant women, aged 18 to 50 years, with singleton pregnancies ≥32+0 weeks gestation (NCT03504189). Simultaneous recording sessions from Invu and cardiotocography lasted for ≥30 minutes. Data from the 8 electrical sensors and 4 acoustic sensors in the Invu belt were acquired, digitized, and sent wirelessly for analysis by an algorithm on cloud-based servers. The algorithm validates the data, preprocesses the data to remove noise, detects heart beats independently from the two data sources (electrical and acoustic), and fuses the detected heart beat arrays to calculate fetal heart rate and maternal heart rate. The primary performance endpoint was Invu fetal heart rate limit of agreement within ± 10 beats per minute (bpm) of fetal heart rate (FHR) measured with cardiotocography. Results A total of 147 women were included in the study analysis. The mean (SD) maternal age was 31.8 ±6.9 years, and the mean gestational age was 37.7 ±2.3 weeks. There was a highly significant correlation between FHR measurements from Invu and cardiotocography (r = 0.92; P Conclusion Although captured by very different methods, the FHR and MHR outputs wirelessly obtained by Invu system through passive methods were very similar to those obtained by the current standard of care. The limits of agreement for FHR measured by Invu were within a clinically acceptable ± 8 bpm of the cardiotocography FHR. The Invu device uses passive technology to allow for safe, non-invasive and convenient monitoring of patients in the clinic and remotely. Further work should investigate how remote perinatal monitoring could best address some of the recent challenges seen with prenatal care and maternal and fetal outcomes.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    28
    References
    9
    Citations
    NaN
    KQI
    []