This study compares the osteointegration of titanium implants coated with bioglass (Biovetro GSB formula) and with hydroxyapatite (HAP). Twenty-four bioglass-coated and 24 HAP-coated cylinders were implanted in the femoral diaphyses of sheep, and examined after 2, 4, 6, 8, 12, and 16 weeks. The HAP coating gave a stronger and earlier fixation to the bone than did bioglass. Bioglass formed a tissue interface which showed a macrophage reaction with little new bone formation activity. In contrast, HAP, showed intense new bone formation, with highly mineralised osseous trabeculae in the neighbourhood of the interface.