Iatrogenic Arteriovenous Fistula Formation after Endovenous Laser Treatment Resulting in High-output Cardiac Failure: A Case Report and Review of the Literature

2020 
Abstract Formation of a clinically significant iatrogenic arteriovenous fistula following endovenous laser treatment of the great saphenous vein is an extremely rare complication. Due to the infrequency of reported cases, there is no clear consensus on how to best manage this complication. We present a unique case of an iatrogenic high-output superficial femoral artery-common femoral vein fistula resulting in right heart failure and a distal deep vein thrombosis. Deployment of a covered arterial stent graft resulted in resolution of the arteriovenous fistula and high-output cardiac state. Clinically significant arteriovenous fistulas resulting from inadvertent vessel injury during endovenous laser treatment appear to be amenable to percutaneous endovascular interventions. During these challenging endovascular cases, intravascular ultrasonography can be utilized to help delineate the morphology of the fistula tract and obtain vessel measurements to ensure accurate endoprosthesis sizing and placement.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    21
    References
    0
    Citations
    NaN