Super-micro-bland particle embolization combined with RF-ablation: Angiographic, macroscopic and microscopic features in porcine kidneys

2012 
Abstract Purpose To describe angiographic, macroscopic and microscopic features of super-micro-bland particle embolization in combination with RF-ablation in kidneys. Thereby, a special focus was given on the impact of the sequence of the different procedural steps. Materials and methods In ten pigs, super-micro-bland particle embolization combined with RF-ablation was carried out. Super-micro-bland embolization was performed with spherical particles of very small size and tight calibration (40 ± 10 μm). In the left kidneys, RF-ablations were performed before embolization (I). In the right kidneys, RF-ablations were performed after embolization (II). The animals were killed three hours after the procedures. Angiographic (e.g. vessel architecture), macroscopic (e.g. long and short axes of the RF-ablations) and microscopic (e.g. particle distribution) study goals were defined. Results Angiography detected almost no vessels in the center of the RF-ablations in I. In II, angiography could not define the RF-ablations. Macroscopy detected significantly larger long and short axes of the RF-ablations in II compared to I (52.2 ± 3.2 mm vs. 45.3 ± 6.9 mm [ P P Conclusion The sequence of the different procedural steps of super-micro-bland particle embolization combined with RF-ablation impacts angiographic, macroscopic and microscopic features in kidneys in the acute setting.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    29
    References
    4
    Citations
    NaN
    KQI
    []