Overview of the 2nd Gen 3.7m HIAD Static Load Test

2015 
To support NASAs long term goal of landing humans on Mars, technologies which enable the landing of heavy payloads are being developed. Current entry, decent, and landing technologies are not practical for human class payloads due to geometric constraints dictated by current launch vehicle fairing limitations. Therefore, past and present technologies are now being explored to provide a mass and volume efficient solution to atmospheric entry, including Hypersonic Inflatable Aerodynamic Decelerators (HIADs). In October of 2014, a 3.7m HIAD inflatable structure with an integrated flexible thermal protection sys-tem (F-TPS) was subjected to a static load test series to verify the designs structural performance. The 3.7m HIAD structure was constructed in a 70 deg sphere-cone stacked-toroid configuration using eight inflatable tori, which were joined together using adhesives and high strength textile webbing to help distribute the loads throughout the inflatable structure. The inflatable structure was fabricated using 2nd generation structural materials that permit an increase in use temperature to 400 C+ as compared to the 250 C limitation of the 1st generation materials. In addition to the temperature benefit, these materials also offer a 40 reduction in structure mass. The 3.7m F-TPS was fabricated using high performance materials to protect the inflatable structure from heat loads that would be seen during atmospheric entry. The F-TPS was constructed of 2nd generation TPS materials increasing its heating capability from 35W sq cm to over 100W sq cm. This test article is the first stacked-torus HIAD to be fabricated and tested with a 70 deg sphere-cone. All previous stacked-torus HIADs have employed a 60o sphere-cone. To perform the static load test series, a custom test fixture was constructed. The fixture consisted of a structural tub rim with enough height to allow for dis-placement of the inflatable structure as loads were applied. The tub rim was attached to the floor to provide an airtight seal. The center body of the inflatable structure was attached to a pedestal mount as seen in Figure 1. Using an impermeable membrane seal draped over the test article, partial vacuum was pulled beneath the HIAD, resulting in a uniform static pressure load applied to the outer surface. During the test series an extensive amount of instrumentation was used to characterize deformed shape, shoulder deflection, strap loads, and cord loads as a function of structural configuration and applied static load. In this overview, the 3.7m HIAD static load test series will be discussed in detail, including the 3.7m HIAD inflatable structure and flexible TPS design, test setup and execution, and finally results and conclusions from the test series.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    0
    Citations
    NaN
    KQI
    []