Ticagrelor Removal From Human Blood
2017
Summary The authors devised an efficient method for ticagrelor removal from blood using sorbent hemadsorption. Ticagrelor removal was measured in 2 sets of in vitro experiments. The first set was a first-pass experiment using bovine serum albumin (BSA) solution pre-incubated with ticagrelor, whereas the second set, performed in a recirculating manner, used human blood mixed with ticagrelor. Removal of ticagrelor from BSA solution reached values >99%. The peak removal rate was 99% and 94% from whole blood and 99.99% and 90% from plasma during 10 h and 3 to 4 h of recirculating experiments, respectively. In conclusion, hemadsorption robustly removes ticagrelor from BSA solution and human blood samples.