Mechanical abnormalities associated with first- and second-generation drug-eluting stent thrombosis analyzed by optical coherence tomography in the national PESTO French registry

2017 
Abstract Background and objectives DES thrombosis may be triggered by different mechanisms that are difficult to identify by angiography alone. This work aimed to investigate and compare the characteristics of stent thrombosis (ST) between 1st- and 2nd-generation drug-eluting stents (DES) among a large cohort of patients explored by optical coherence tomography (OCT). Methods and results The PESTO study was a prospective national registry involving 29 French catheterization facilities. Patients with acute coronary syndromes were prospectively screened for presence of definite ST and analyzed by OCT after culprit lesion deocclusion. The analysis involved 71 subjects including 34 patients with 1st-generation DES (DES1G) and 35 patients with 2nd-generation DES (DES2G). Most patients (80%) presented with very late stent thrombosis. The median time between initial PCI and ST was longer in DES1G than DES2G patients (3.8 [2.6–6.5] years vs. 1.1 [0.04–2.3] years, p p =0.008). There was no significant difference in percentage of malapposed struts and uncovered struts between groups. Conclusions In this registry, DES thrombosis mainly occurred ≥1year after initial PCI. OCT identified a mechanical abnormality in the vast majority of the cases. Similar causes were observed between DES1G and DES2G, but neoatherosclerotic lesions were more common in DES1G.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    23
    References
    9
    Citations
    NaN
    KQI
    []