Screening for Early-Stage Parkinson's Disease: Swallow Tail Sign on MRI Susceptibility Map-Weighted Images Compared With PET.

2020 
Background Swallow tail sign (STS) on MRI is presumed to be an imaging biomarker of nigrosome-1, which may exhibit a similar role as positron emission tomography (PET), indicating dopaminergic degeneration. Purpose To investigate whether an alteration of STS could serve as an alternative screening sign compared with PET in the diagnosis of early-stage Parkinson's disease (esPD). Study type Prospective. Population Thirty-seven patients with esPD and 27 age- and sex-matched healthy controls (HCs). Field strength/sequence Quantitative susceptibility mapping images were collected on 3T MRI and [18 F]9-fluoropropyl-(+)-dihydrotetra-benazine PET images were acquired using a 64 rings PET/CT scanner. Assessment Alterations of STS and striatal uptake in each hemisphere were visually rated on a 0-2 points scale. Point 2: normal appearance of STS/normal striatal uptake; Point 1: partial loss of STS/uptake reduction confined to the putamen; Point 0: total loss of STS/uptake reduction extended to the caudate nucleus. The concordance rate of STS rating and ipsilateral striatal binding was calculated at the nuclei level. At the participant level, an evaluation rating was calculated by adding the STS ratings from both hemispheres to distinguish esPD from HCs. Statistical tests The intra- and interobserver agreement were tested using Cohen's kappa and the intraclass correlation coefficient. Hotelling's T-squared test was used to compare the difference of rating points. Receiver operating characteristic analysis was performed to evaluate the diagnostic power. Results The intra- and interobserver agreement for STS and striatal uptake rating was over 0.75. There was no significant difference of rating point distribution (P = 0.084). The concordance rate was 94.3% for the right side and 91.4% for the left. Using bilateral partial loss of STS as the threshold, the achieved sensitivity and specificity for discriminating esPD from HCs were 94.59% and 92.49%, respectively. Data conclusion STS alterations corresponded well with striatal uptake on PET in esPD, and our proposed evaluation scale of STS had satisfactory diagnostic performance in discriminating the disease. Level of evidence 2 TECHNICAL EFFICACY: Stage 2.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    33
    References
    0
    Citations
    NaN
    KQI
    []