Removal of intra-abdominal mislocated intrauterine devices by laparoscopy

2011 
This retrospective study was carried out on 15 patients who underwent laparoscopy for the removal of a mislocated IUD from 2003 to 2009. The mean duration of usage of an IUD was 16.1 months. The IUD was found in the Pouch of Douglas in six patients; in the posterior wall of the uterus in three patients; in the adnexa in three patients; in the omentum in two patients and it was embedded in the rectal serosa in one patient. The types of the IUDs were TCu-380A (n = 13) and Mirena® (n = 2). The mean laparoscopic operation time was 25 min. No major complications occurred. A second ancillary port was required in three patients. All patients were discharged within 24 h. Laparoscopic removal of the intra-abdominal IUD must be the first choice of therapy. If possible, a single ancillary port should be preferred for the removal of mislocated IUDs. We advise that surgical removal and surgical risk should be discussed with the patients, even if asymptomatic.