Successful retrieval of an irretrievable jugular tesio catheter using a fogarty arterial embolectomy catheter.

2014 
Long life expectancy and wide development of therapies have increased the number of patients under artificial treatment for lost kidney function or dialysis. Different options for vascular access are suitable for receiving this therapy. The use of tunneled catheters has consequently increased complications related to its use. A difficult retrieval of catheters caused by a hard fibrin sheath along its trajectory is a common drawback. Herein, we report a woman with suspicion of hemodialysis catheter infection and an irretrievable Tesio catheter. A novel technique using a Fogarty arterial catheter allowed a successful retrieval and avoided an aggressive management.