Magnetic Resonance–Augmented Cardiopulmonary Exercise Testing

2016 
Background—Conventional cardiopulmonary exercise testing can objectively measure exercise intolerance but cannot provide comprehensive evaluation of physiology. This requires additional assessment of cardiac output and arteriovenous oxygen content difference. We developed magnetic resonance (MR)–augmented cardiopulmonary exercise testing to achieve this goal and assessed children with right heart disease. Methods and Results—Healthy controls (n=10) and children with pulmonary arterial hypertension (PAH; n=10) and repaired tetralogy of Fallot (n=10) underwent MR-augmented cardiopulmonary exercise testing. All exercises were performed on an MR-compatible ergometer, and oxygen uptake was continuously acquired using a modified metabolic cart. Simultaneous cardiac output was measured using a real-time MR flow sequence and combined with oxygen uptake to calculate arteriovenous oxygen content difference. Peak oxygen uptake was significantly lower in the PAH group (12.6±1.31 mL/kg per minute; P=0.01) and trended ...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    2
    Citations
    NaN
    KQI
    []