A medium speed mill-foundation coupled finite element model was established using ANSYS. The modal and harmonic responses of medium-speed mill were analyzed. The influence of the number of vibration isolators and the ratio of foundation bedplate to equipment on the vibration of mill was analyzed. The shock absorption measures of medium-speed mills were discussed. To get good vibration isolation effect, the maximum horizontal vibration displacement of medium-speed mill with spring vibration-isolated foundation is suggested as 50 μm, and the ratio of foundation bedplate to equipment as 3.0±0.2.