A comparison of 24-hour urine versus random urine samples for determination and quantification of Bence Jones protein in a South African population.

2019 
Background The International Myeloma Working Group and College of American Pathologists recommend a 24-h urine collection to determine the Bence Jones protein (BJP) excretion level for monitoring treatment response in patients with multiple myeloma (MM). There are several issues related to sample collection and the method is prone to inaccuracy. Objective This study compared measured 24-h to random urine collections for the quantitation of BJP in a South African population. Methods Sixty-six patients with MM submitted random urine samples with their routine 24-h urine collection from April 2016 - March 2018. Measured 24-h urine BJP was compared to two estimated 24-h BJP excretions calculated as follows: Estimation 1 (E1): Estimated 24-h BJP (mg/24 h) = Urine BJP/Creatinine ratio (mg/mmol) × 10. Estimation 2 (E2): Estimated 24-h BJP (mg/24 h) = Urine BJP/Creatinine ratio (mg/mmol) × 15 mg/kg for women or × 20 mg/kg for men. Results Correlation of estimation equations E1 and E2 to the measured 24-h urine BJP was 0.893. Patients showed no difference in classification of treatment response using either the E1 or E2 estimation equations when compared to the measured 24-h urine BJP results. Conclusion This study demonstrates that the estimated 24-h BJP shows a high degree of correlation with the measured 24-h BJP and can likely be used to monitor treatment response in South African patients with MM.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    24
    References
    0
    Citations
    NaN
    KQI
    []