Post-transplantation outcomes of sensitized patients receiving durable mechanical circulatory support

2021 
Abstract Background Sensitization, defined as the presence of circulating antibodies, presents challenges, particularly in patients undergoing heart transplantation (HTx) bridged with durable mechanical circulatory support (MCS). We aimed to investigate the post-transplantation outcomes of sensitized MCS patients. Methods Among 889 consecutively enrolled heart transplant (HTx) recipients between 2010 and 2018, 86 (9.7%) sensitized MCS patients (Group A) were compared with sensitized non-MCS patients (Group B, n = 189), non-sensitized MCS patients (Group C, n=162), and non-sensitized non-MCS patients (Group D, n = 452) regarding post-HTx outcomes, including the incidence of primary graft dysfunction (PGD), 1-year survival, and 1-year freedom from antibody-mediated rejection (AMR). Results Sensitized MCS patients (Group A) showed comparable rates of PGD, 1-year survival, and 1-year freedom from AMR with Groups C and D. However, Group A showed significantly higher rates of 1-year freedom from AMR (95.3% vs. 85.7%, P = 0.02) and an earlier decline in panel-reactive antibody (PRA) levels (P Conclusions Sensitized MCS patients showed significantly lower rates of AMR and an earlier decline in PRA levels following HTx than sensitized non-MCS patients. Removal of MCS at the time of transplantation might underlie these observations.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    30
    References
    0
    Citations
    NaN
    KQI
    []