Association of Visceral Fat Area Measured by InBody 720 with the Results Measured by CT, DEXA and Anthropometric Measurement

2010 
1 Inje University Haeundae Paik Hospital, Busan, Korea Background: Obesity is associated with various chronic diseases, especially abdominal fat affect cardiovascular disease, metabolic disease, diabetes mellitus and mortality. The aim of this study was to estimate the accuracy of the visceral fat area measured by bioelectric impedence analysis (BIA) that easily used in many clinical settings, and to compare with the visceral fat area measured by CT and other abdominal obesity measures. Methods: Participants were 71 premenopausal adult women whose BMI was over 23 kg/m 2 . BMI, waist circumference, total abdominal fat area, visceral fat area, subcutaneous fat area by CT and truncal fat by dual-energy X-ray absorptiometry (DEXA) were measured. Visceral fat area measured by Inbody 720 were compared with variables examining abdominal obesity using partial correlation analysis and Bland-Altman analysis. The accuracy of the visceral obesity by BIA was compared with that diagnosed by CT as gold standard. Results: There was significant difference between visceral fat area measured by CT and BIA in women below BMI 30
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    23
    References
    6
    Citations
    NaN
    KQI
    []