Background In this methodology article a thermal threshold testing device designed to test nociception in cats was assessed in six dogs. The purpose of this study was to investigate baseline reproducibility of thermal thresholds obtained by the contact heat testing device, to assess the influence of acepromazine and levomethadone and fenpipramide in dogs. The relationship between change in nociceptive thermal threshold and the opioid′s plasma concentration was determined. Six adult beagle dogs received levomethadone (0.2 mg/kg), acepromazine (0.02 mg/kg) or saline placebo by intramuscular injection (IM) in a randomized cross-over design. Three baseline nociceptive thermal threshold readings were taken at 15 minutes intervals prior to treatment. Further readings were made at 15, 30, 45, 60, 90, 120, 150, 180, 210, 240, 270, 300, 330, 360, 420 and 480 minutes after injection. A sedation score was assigned at every reading. Four saline placebo treatments were performed to assess baseline reproducibility. Levomethadone serum concentrations were measured prior and 0.5, 1, 2, 4, 8, 12 and 24 hours after drug dosing in a separate occasion.