Evaluation of Two Measurement Techniques to Quantify Fuel-Air Mixing of a Gas Turbine Pre-Mixer at Atmospheric Conditions

2015 
In the present study, two measurement techniques are adopted to evaluate the fuel-air mixing under atmospheric conditions using an industrial fuel-air pre-mixer. These techniques are CO2 mixing and Planar Laser Induced Fluorescence (PLIF) in water. In these techniques, CO2 and fluorescent dye are injected as fuel simulants. CO2 measurements are used to validate PLIF in water. In the CO2 technique, CO2 concentrations are converted to fuel mass fractions whereas, in the PLIF technique, a modified post processing method is used to convert the LIF signal into fuel mass fraction. The experiments are conducted at the same Reynolds number and momentum flux ratio for two injection strategies. To study the effect of the flow aerodynamics on the mixing results, high speed PIV measurements are conducted in water at the same Reynolds number. A comparison of fuel concentrations measured with the CO2 and PLIF techniques shows good quantitative agreement at all momentum flux ratios. However, deviations between the two techniques are observed at high fuel concentration gradients. The unsteady mixing is evaluated using PLIF technique with high temporal resolution. Analysis of PIV and PLIF data shows that unsteady mixing is lower at regions of high fluctuations in velocity. Moreover, it is found that there is high unsteady mixing at locations where there is high concentration gradient.Copyright © 2015 by ASME