High Right Atrial Pressure and Low Pulse Pressure Predict Gastrointestinal Bleeding in Patients With Left Ventricular Assist Device

2018 
Abstract Background Gastrointestinal bleeding (GIB) remains a major morbid event during continuous flow left ventricular assist device (LVAD) support. This study investigated whether a common hemodynamic profile is associated with GIB in patients with LVADs. Methods and Results A single institution analysis reviewed all patients who underwent right heart catheterization (RHC) following LVAD implant between January 1, 2006, and December 31, 2013, with follow-up through June 2015. Kaplan-Meier and multiphase hazard statistical methods were employed. Among 108 patients with 341 RHC, 55 hospitalizations for GIB occurred within 1 year of RHC. Freedom from GIB at 6 months was 92% in patients with pulse pressure ≥35 mmHg, compared with 76% with pulse pressure  P Conclusions Greater pulsatility and less venous congestion, along with other factors, are associated with a lower risk for GIB. It is reasonable to adjust therapeutic strategies to target this hemodynamic profile in patients with a propensity for GIB.