Aortic Valve Gradient and Clinical Outcome in Patients Undergoing Transcatheter Aortic Valve Implantation for Severe Aortic Stenosis
2016
Objectives: To explore the relation between the baseline aortic valve gradient (AVG) as a continuous variable and clinical outcomes following transcatheter aortic valve implantation (TAVI) in general and specifically in patients with high-gradient aortic stenosis (AS). Methods: We reviewed 317 consecutive patients who underwent TAVI at our institution. We investigated the relation between AVG as a continuous/categorical variable and outcome among all patients and in patients without low-flow low-gradient AS, using the Cox proportional hazard model adjusting for multiple prognostic variables. Results: Patients had a peak AVG of 79.9 ± 22.8 mm Hg (mean 50.5 ±15.7). During a mean follow-up of 2.7 years, AVG was inversely associated with mortality and mortality or cardiac hospitalization. Every 10-mm-Hg increase in peak AVG was associated with 18% reduction in mortality (p = 0.003) and 19% reduction in mortality/cardiac hospitalization (p 40% or peak AVG >64 mm Hg yielded similar results. Conclusions: Mean and peak baseline AVGs are directly associated with improved outcomes after TAVI; AVG can be used to select the patients most likely to benefit from TAVI.